1 Unit : €1500.00 |
Save! 2 Units : 2900.00 |
Save! 3 Units: 4000.00 |
|
|
|
|
|
Automaticaly Document Results
|
Comprehensive on board memory |
|
Portable printer kits provide real time documentation |
|
Computer interface via DataTrak software |
Customizable
|
Password Protection |
|
Calibration/Cal Check Reminder |
|
Calibration/Cal Check Lock out |
|
Records Batch ID, Subject ID or both |
|
Trigger Mode Options: choose from "End-of-Breath" or "Precise Volume" |
|
Selectable Test Order |
|
Air Blank Option |
Proven and Reliable
|
Full Size Fuel Cell |
|
Alcohol Specific |
|
Recertification Program keeps your FC20 like new with the latest software and features |
Versatile and Complete
|
Printing options: choose from direct printing or DataTrak computer interface |
|
Three Test Modes: Automatic,Manual and Passive |
|
Numerous additional user selectable options |
Full Graphic LCD Display
The large easy-to-read LCD display on the FC20 gives it the unique ability to display information. Through this display the FC20 "talks" to the operator with plain-English prompts, breath flow graphs and alcohol graphs.
FC20
All the standard features of the FC10Plus including a premium full sized fuel cell sensor to prevent false positives and assure long life, patented digital technology providing 10-second response time and unlimited numbers of repeat tests in addition to Auto, Manual or Passive testing modes.
Memory
On board memory stores the last 500 tests and a built in real time clock stores the time and date of each test along with the current calibration check results. These results can be downloaded into a computer or sent directly to a printer for instant readout.
Calibration voucher
As with all serious gas measurement sensors the LifeLoc FC Series must be re-calibrated from time to time : Approx every 6 - 12 months or 300 - 400 uses depending on usage.
Be careful !
Some cheaper units purport not to require calibration. It is impossible to maintain the accuracy of a breathalyser without service, these units are mere novelty devices often sold by electronics importers who know little or nothing about toxicology.
Some units also require a replaceable sensor. Replacing the sensor is just 50% of the service – the units hardware and software device be checked to make sure it is working properly. Users should be wary of devices that have no back-up servicing from manufacturers.
Keeping your Lifeloc FC10 Plus in check couldn’t be easier:
Send us a Calibration voucher (purchase a voucher for 100 Euro when purchasing your unit)
A cheque, postal order, bank draught or cash to
MTC Healthcare Ltd. 34 – 35 Ormond Quay Lower, Dublin 1, Ireland.
Call (01) 8748699 to purchase by credit card
. : |
Once we receive your unit we give it a health check and even update the software to make sure your unit is kept up- to- date. |
. : |
You will have your unit as good as new within 3 working days. |
Specifications
| 1 |
Sensor |
High Quality Advanced Electrochemical Fuel Cell -Alcohol specific. |
| 2 |
Pump |
Automatically actuated electronic pump system. No cocking required. |
| 3 |
Units of Measure |
BAC Standard. Factory can set to any other common unit of measure. |
| 4 |
Response Time |
Immediate on negatives, under 10 seconds on positives. |
| 5 |
Recovery Time (ready for next test) |
Immediate on negatives, under 30 seconds on positives. |
| 6 |
Accuracy |
DOT Approved at +/- .005BAC to +/- 5% above a .100BAC. |
| 7 |
Operating Temperature Range |
32-105 degrees F (0-40C) |
| 8 |
Self Diagnostics |
Programmed self-check assures unit is operational upon power-up. |
| 9 |
Size |
2.6 x 5 x 1.25 inches (66 x 127 x 33 mm). |
| 10 |
Weight |
.56 lbs. (255 grams) |
| 11 |
Warranty |
One year limited warranty; parts and labor. |
| 12 |
Detection Range |
.000 to .600 BAC |
| 13 |
Power |
4AA Alkaline Batteries. Up to 8000 tests per battery set. Internal Lithium battery powers real time clock (FC20). |
| 14 |
Display |
1.7 x .85 inch viewing area graphic LCD. Extended temperature range.
Automatic backlight for nighttime use |
| 15 |
Mouthpieces |
Disposable. |
| 16 |
Memory |
Permanent data storage survives on/off function or battery removal/failure. Last test retention (FC10, FC10Plus)
Last 500 test retention and associated test data (FC20) |
| 17 |
Printer (included with kit) |
Accommodates 3-part paper. Rechargeable battery powered (charger included). Auto shut-off to preserve battery life. Automatic start integrated with the FC20. |
|
1 Unit : €1500.00 |
Save! 2 Units : 2900.00 |
Save! 3 Units: 4000.00 |
|
|
|
|
|
Disclaimer
A. |
The Manufacturer, Retailers and MTC Healthcare Ltd., make no warranties, express or implied as to the ability of the device to determine whether a user of this product is legally intoxicated, and MTC Healthcare expressly disclaims any liability for incidental, special, or consequential damages of any nature. |
|
|
B. |
Decisions and/or actions based upon the reading of this device shall be entirely the person’s own risk.
|
|
|
C. |
The manufacturer, retailers and MTC Healthcare Ltd., make no warranties express or implied that Alcologic, Alcologic Cellpro,Lifeloc FC10 Series, Lifeloc FC20 Series or any modification or adjustment thereof is a legal protector or evidence or defence against any police or public pro cedure or judicial or investigative proceedings in any jurisdiction. |
|
|
D. |
The manufacturer, retailers and MTC Healthcare Ltd., does not warrant the veracity of the readings of the Alcologic, Alcologic Cellpro,Lifeloc FC10 Series, Lifeloc FC20 Series units as evidence.. |
|
|
E. |
The manufacturer, retailers and MTC Healthcare Ltd., assumes no responsibility for users who test negative when and later show that they are under the influence of alcohol or are proven to be intoxicated by alcohol. |
| |
|
| |
|
|
|